5.AUTOMATIC OPERATION B-63323EN-1/03
- 490 -
3. When BDTn, currently set to 1, is set to 0 while the CNC is
reading a block containing /n, the block is ignored.
4. When two or more optional block skip switches are specified in a
block and BDTn, corresponding to one of them, is set to 1, the
block is ignored.
Signal
Optional block skip Signal
BDT1<G004#2>,BDT2-BDT9<G007>
[Classification] Input signal
[Function] Select whether a block containing /n is to be executed or ignored.
[Operation] During automatic operation, a block containing /n in the program is
ignored when the corresponding optional block skip signal is set to 1. It
is executed normally when the signal is set to 0.
BDTn
"0"
Reading by CNC?. . . . . . ; /n N123 X100. Y200. ; N234 . . . . . .
Ignored
BDTn
"0"
Reading by CNC?
. . . . . . ; /n N123 X100. Y200
.; N234. . . . . .
Ignored
BDT3
"0"
Reading by CNC?. . . . . .
; /1 /3 /5 N123 X100. Y200.
; N234 . . . . .
Ignored