10.TOOL FUNCTION B-63323EN-1/03
- 974 -
Alarm and message
Number Message Contents
PS0437 ILLEGAL LIFE GROUP NUMBER A tool group number exceeded the maximum value.
The tool group No. (P after G10 L3:) or the group No.
assigned by the T code instruction for tool life management
in the machining program exceeded the maximum value.
PS0438 GROUP NOT FOUND AT LIFE DATA A tool group specified in the machining program was not set
in the tool life management data.
PS0439 OVER MAXIMUM TOOL NUMBER The number of tool specified in a single tool group exceeds
the maximum allowed number.
PS0440 T COMMAND NOT FOUND No T command was specified in a program which sets a tool
group.
The same block as M06 in the machining program does not
contain a T command in tool change method D (parameters
CT2=2, CT1=1: No. 7401#1/#0).
PS0441 NOT USING TOOL IN LIFE GROUP An H99 instruction, D99 instruction or the H/D code specified
in parameters (No. 7443, 7444) has been specified even
though no tool that belongs to a group was being used.
PS0442 ILLEGAL T COMMAND AT M06 The tool group of the tool specified in the tool instruction
(return tool group) after the M06 instruction in the machining
program does not match the current tool group in tool
change method A (parameters CT2=0, CT1=0: No.
7401#1/#0).
This alarm can be suppressed by setting ABT parameter No.
7400#6 to "1".
PS0443 P,L COMMAND NOT FOUND No P (group No. ) or L (tool life) was specified at the
beginning of a program that sets a tool group when tool data
in a group was being loaded during loading tool life
management data.
PS0444 OVER MAXIMUM LIFE GROUP The number of blocks in which P (group No. ) or L (tool life) is
instructed exceeding the maximum number of groups was
found while loading tool life management data.
PS0445 ILLEGAL L COMMAND An illegal range instructed in the L (tool life) instruction was
found while loading tool life management data.
PS0446 ILLEGAL H,D,T COMMAND A value specified by T (tool No. ), D (cutter compensation
No. ) or H (tool length offset No. ) exceeding the maximum
value was found while loading tool life management data.
PS0448 ILLEGAL FORMAT AT LIFE DATA An illegal address was specified in a program (G10 L3: to
G11;) that sets a tool group.
Allowable addresses are P (group No. ), L (tool life) and T
(tool No. ).
PS0449 ILLEGAL TOOL LIFE DATA Tool life management data is damaged for some reason.
Reload the tool group and the corresponding tool data by
G10 L3; or MDI input.
Reference item
Series15i/150i-MA Operator’s Manual
(Programming)
(B-63324EN)
II-10.2 Tool life management