14.PMC CONTROL FUNCTION B-63323EN-1/02
- 1392 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
2217 NOM
!!"" !"!""#
""# !$%&"""
"'())*+
), !%+
-, " !%+
Alarm and message
Number Message Contents
OT0120 UNASSIGNED ADDRESS (HIGH) The upper 4 bits (EIA4 to EIA7) of an external data I/O
interface address signal are set to an undefined address
(high bits).
OT0121 UNASSIGNED ADDRESS (LOW) The lower 4 bits (EIA0 to EIA3) of an external data I/O
interface address signal are set to an undefined address
(low bits).
OT0122 TOO MANY MESSAGE Requests were made to display more than 4 external
operator messages or external alarm messages at the
same time.
OT0123 MESSAGE NUMBER NOT FOUND An external operator message or external alarm message
cannot be canceled as no message No. is specified.
OT0124 OUTPUT REQUEST ERROR An output request was issued during external data output,
or an output request was issued for an address that has no
output data.
OT0125 TOO LARGE NUMBER A numerical value outside the range 0 to 4095 was
specified as the No. for the external operator message or
an external alarm message.
OT0126 SPECIFIED NUMBER NOT FOUND [External data I/O]
The No. specified for a program No. or sequence No.
search could not be found.
There was an I/O request issued for a pot No. or offset (tool
data), but either no tool numbers have been input since
power ON or there is no data for the entered tool No.
[External workpiece No. search]
The program corresponding to the specified workpiece No.
could not be found.
OT0127 DI.EIDHW OUT OF RANGE The numerical value input by external data input signals
EID32 to EID47 has exceeded the permissible range.
OT0128 DI.EIDLL OUT OF RANGE The numerical value input by external data input signals
EID0 to EID31 has exceeded the permissible range.