1.AXIS CONTROL B-63323EN-1/03
- 58 -
- Compensation data
Compensation data is set using 128 straightness compensation points.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
5426 IPC
[Input type] Parameter input
[Data type] Bitaxis
# 6 IPC Specifies whether to use the interpolating straightness compensation
function.
0: Do not use.
1: Use.
This parameter is valid only when it is set for those move axes
(controlled axis numbers set in parameter No. 5481 to No. 5485).
Alarm and message
Number Message Contents
PW0100 ILLEGAL PARAMETER (S-COMP.)
The parameter for setting slope compensation is incorrect.
This alarm occurs in the following cases:
• The axis number specified in the movable or
compensation axis parameter does not correspond to
any existing axis.
• When the number of pitch error compensation points on
the axis on which slope compensation is executed
exceeds 128 between the most negative side and most
positive side
• When the size relationship between the slope
compensation point Nos. is incorrect
• When the slope compensation point is not located
between the most negative side and most positive side of
pitch error compensation
• When the compensation per compensation point is too
small or too great.
SV0100 S-COMP. VALUE OVERFLOW
The value set for straightness compensation has exceeded
maximum value 32,767.