5.AUTOMATIC OPERATION B-63323EN-1/03
- 480 -
Dry run check signal
MDRN<F004#1>
[Classification] Output signal
[Function] Reports the state of the dry run signal.
[Output condition] This signal is set to 1 in the following case:
- When dry run signal DRN is set to 1
This signal is set to 0 in the following case:
- When dry run signal DRN is set to 0
- Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G004 DRN
F004 MDRN
Parameter
1410 Dry run feedrate
[Input type] Parameter input
[Data type] Real
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(0.0 to +240000.0 in the IS-B)
Set the dry run feedrate when the jog feedrate dial is set to 100%.
The unit of data depends on the increment system of the reference
axis.
#7 #6 #5 #4 #3 #2 #1 #0
1400 LRP TDR RDR
+,$&+%,&,&
+&!
*%,&!
" *%,&!
" +,$&+%,&,&&
+&!
*%,&!
" *%,&!