B-63323EN-1/03 11.PROGRAM COMMAND
- 1093 -
2431 M code to execute external device subprogram calls
(%
%
)% ;22222222
(0''5%/
$0#280#$01$0,$028$022
''5%/%5$#$
1$,$28$22$0#28''
5%
Alarm And message
Number Message Contents
PS0590 TH ERROR A TH error was detected during reading from an input
device.
The read code that caused the TH error and how many
statements it is from the block can be verified in the
diagnostics screen.
PS0591 TV ERROR An error was detected during the single-block TV error.
The TV check can be suppressed by setting TVC
parameter No. 0000#0 to "0".
PS0592 END OF RECORD The EOR (End of Record) code is specified in the middle of
a block.
This alarm is also generated when the percentage at the
end of the NC program is read.
Reference item
Series15i/150i-MA Operator’s Manual
(Programming)
(B-63324EN)