13.MEASUREMENT B-63323EN-1/03
- 1316 -
1843 Position deviation limit at torque limit skip
;
7! !
>!! ($40BB(
!1!C3!
;*!1;!!1
#>(,(?%!!*
Alarm and message
Number Message Contents
PS0150 G31 FORMAT ERROR • No axis is specified or tow or more axes are specified in
the torque limit switch instruction (G31P98/P99).
• The specified torque Q value in the torque limit switch
instruction is out of range. The torque Q range is 1 to 99.
PS0151 CANNOT USE G31 The alarm occurs in the following cases:
• The G31 code cannot be specified. The G code in group
07 (e.g. cutter compensation) is not canceled.
• The torque limit was not specified by the torque limit skip
instruction (G31 P98/P99). Either specify the torque limit in
the PMC window, or specify torque limit override by
address Q.
SV0109 EXCESS ERROR (G31) The position deviation during execution of torque limit
switch operation exceeds the limit setting of parameter No.
1843.
Reference item
Series15i/150i-MA Operator’s Manual
(Programming)
(B-63324EN)
II-16.6 Torque limit skip