B-63323EN-1/03 2.PREAPARATIONS FOR OPERATION
- 311 -
(I,J,K)
(X,Y,Z)
G 22X_ Y_ Z_ I_ J_ K_ ;
X-I>ζ
Y-J>ζ
Z-K>ζ
ζ : Movement value / 8 msec
2.0mm when speed is 15m/min.
Fig. 2.3.3 (b) Creating or changing the forbidden area using a program
When setting the area by parameters, points A and B in the figure
below must be set.
B
(X2,Y2,Z2)
A(X1,Y1,Z1)
X1-X2>ζ
Y1-Y2>ζ
Z1-Z2>ζ
ζ : Movement value / 8 msec
2.0mm when speed is 15m/min.
Fig.2.3.3(c) Creating or changing the forbidden area using a parameters
In stored stroke check 2, even if you mistake the order of the coordinate
value of the two points, a rectangular, with the two points being the
apexes, will be set as the area.
When you set the forbidden area through parameters (Nos. 5222, 5223),
the data should be specified by the distance from the machine
coordinate system in the least command increment. (Output increment)
If it is set by a G22 command, specify the data by the distance from the
machine coordinate system in the least input increment (Input
increment.)
The programmed data are then converted into the numerical values in
the least command increment, and the values are set as the parameters.
- Checkpoint for the forbidden area
Confirm the checking position (the top of the tool or the tool chuck)
before programming the forbidden area.
If point A (The top of the tool) is checked in Fig. 2.3.3 (d) , the distance
"a" should be set as the data for the stored stroke limit function. If point
B (The tool chuck) is checked, the distance "b" must be set. When
checking the tool tip (like point A), and if the tool length varies for each