B-63323EN-1/03 9.SPINDLE FUNCTION
- 805 -
- For 1st spindle
#7 #6 #5 #4 #3 #2 #1 #0
G026 GS4A GS2A GS1A *SECLPA*SEUCLA SPSTPA
G227 CTH1A CTH2A
F042 SCLPA SUCLPA
- For 2nd spindl
#7 #6 #5 #4 #3 #2 #1 #0
G272 GS4B GS2B GS1B *SECLPB*SEUCLB SPSTPB
G235 CTH1B CTH2B
F338 SCLPB SUCLPB
- For 3rd spindl
#7 #6 #5 #4 #3 #2 #1 #0
G211 CTH1C CTH2C
G273 GS4C GS2C GS1C *SECLPC*SEUCLC SPSTPC
F339 SCLPC SUCLPC
- For 4th spindle
#7 #6 #5 #4 #3 #2 #1 #0
G219 CTH1D CTH2D
G274 GS4D GS2D GS1D *SECLPD*SEUCLD SPSTPD
F340 SCLPD SUCLPD
Sequence (time chart)
Spindle orientation
To cancel spindle rotation mode then enter spindle positioning mode,
specify Mxx in a program.
xx must be set in parameter No. 5680 in advance. The sequence pattern
must be set in parameter No. 5895.
1. Assume that Mxx is programmed.
2. A miscellaneous function code signal M0 to M31 is sent, and at
the same time, miscellaneous function strobe signal MF is set to 1.
This sending procedure is the same as that for ordinary
miscellaneous functions.
3. When strobe signal FM is set to 1, the PMC reads the code signal.
After confirming that the code signal is xx, the PMC must respond
appropriately. For example, suppose that Mxx is specified while
the spindle is rotating. The PMC may respond in either of two