1.AXIS CONTROL B-63323EN-1/03
- 144 -
- Axis setting screen
On the axis setting screen, the following items can be specified:
• M1 : connector number for pulse module 1
For an axis that uses pulse module 1, enter a connector
number using a number in the range of between 1 and the
maximum number of axes for pulse module 1. When pulse
module 1 need not be used, enter 0. If a number that falls
outside the valid range is entered, the message FORMAT
ERROR is displayed.
• M2 : connector number for pulse module 2
For an axis that uses pulse module 2, enter a connector
number using a number in the range of between 1 and the
maximum number of axes for pulse module 2. When pulse
module 2 need not be used, enter 0. If a number that falls
outside the valid range is entered, the message FORMAT
ERROR is displayed.
• 1DSP
Enter 1 for the following axes, each of which exclusively
uses a DSP, which is usually shared by two axes. If a number
other than 0 or 1 is entered, the message FORMAT ERROR
is displayed.
- High-speed current loop axis
- High-speed interface axis
• SPOS
When setting a spindle positioning axis, enter a spindle
number from 1 to 4. If a number other than 0 to 4 is entered,
a warning indicating that the data falls outside the valid
range is issued.
• CS
Enter spindle number ( 1 to 4 ) for the Cs contour controlled
axis. If a number other than number other than 0 to 4 is
entered, the message FORMAT ERROR is displayed.
• TNDM
Enter odd and even numbers for the master and slave axes
for tandem control. These numbers must be consecutive and
in the range of between 1 and number of controlled axis. If a
number that falls outside the valid range is entered, the
message FORMAT ERROR is displayed.
• EGB
When using the EGB function, enter successive odd and
even numbers for the slave and dummy axes. Numbers from
1 to the number of controlled axes may be entered. If a
number that falls outside the range is entered, a warning
indicating that the data is not within the valid range is issued.
When the [AUTO SETING] soft key is pressed on the axis setting
screen after data entry, the message DATA IS OUT OF RANGE
is displayed if any of the following conditions is satisfied.
• Both M1 and M2 are nonzero for an axis.
• Any two of the 1-DSP, SPOS, CS, TNDM, and EGB are
nonzero for an axis.
• A duplicate value is specified for M1.