B-63323EN-1/03 1.AXIS CONTROL
- 229 -
Section 4.29, "Parameters Related to the Five-Axis Control
Function"
Set the parameters for head 2 in the same way as the parameters for
head 1.
- Parameters related to a twin table
Parameter number Data type Description
7702 Integeraxis Master axis number
7633 Integer M code for turning synchronization off
7634 Integer M code for turning synchronization on
7642 Integer M code for specifying independent
operation
For details of each parameter, refer to the following manual:
Parameter Manual, B-63330EN
Section 4.30, "Other Parameters"