B-63323EN-1/03 1.AXIS CONTROL
- 221 -
7642 M code that causes switching to independent operation
during twin table control
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 999999999
Specify the M code that causes switching from synchronous or
normal operation to independent operation.
The M code specified for this parameter is handled as an M code
without buffering.
7702 Master axis number in synchronous control or twin table
control
NOTE
After this parameter has been set, the power must
be off turned off then back on for the setting to
become effective.
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - Max axes
Select an axis that is to be synchronized in synchronous control or
twin table control.
Example: Assume the following controlled axis configuration:
First axis : X-axis
Second axis : Y-axis
Third axis : Z-axis
Fourth axis : U-axis
To synchronize the U-axis with X-axis, set the parameters as
follows:
X: 0
Y: 0
Z: 0
U: 1