11. PROGRAM COMMAND B-63323EN-1/03
- 1116 -
7096 Start M code used to call a subprogram
7097 Start program number of a subprogram called by M code
7098 Number of M codes used to call subprograms (number of subprograms
called by M codes)
0
4&& ." !9#F!!!!!!!!
." !#$F!!!!!!!!
." !(# F39
Set this parameter to define multiple subprogram calls using M codes at a time.
With M codes as many as the value set in parameter No. 7098 starting with the M
code set in parameter No. 7096, the subprograms of program numbers as many as
the value set in parameter No. 7098 starting with the program number set in 7097
can be called. Set 0 in parameter No. 7098 to disable this mode of calling.
Example 1:
When parameter No. 7096 = 80000000, parameter No. 7097 = 30000000, and
parameter No. 7098 = 100 are set, a set of 100 subprogram calls is defined as
follows:
M80000000 -> O30000000
M80000001 -> O30000001
M80000002 -> O30000002
:
M80000099 -> O30000099
NOTE
1. When the following conditions are satisfied, all calls using these
parameters are disabled:
(1) When a value not within the specifiable range is set in
each parameter
(2) (Value of parameter No. 7097 + value of parameter No.
7098 - 1) > 99999999
2. If a range of M codes set by these parameters duplicate M codes
specified in parameter No. 7071 through No. 7079, the calls
specified by parameter No. 7071 through 7079 are made
preferentially.