B-63323EN-1/03 1.AXIS CONTROL
- 291 -
Parameters
1120 Address translation table value (ATR) for slave 1 (second FSSB)
1121 Address translation table value (ATR) for slave 2 (second FSSB)
1122 Address translation table value (ATR) for slave 3 (second FSSB)
1123 Address translation table value (ATR) for slave 4 (second FSSB)
1124 Address translation table value (ATR) for slave 5 (second FSSB)
1125 Address translation table value (ATR) for slave 6 (second FSSB)
1126 Address translation table value (ATR) for slave 7 (second FSSB)
1127 Address translation table value (ATR) for slave 8 (second FSSB)
1128 Address translation table value (ATR) for slave 9 (second FSSB)
1129 Address translation table value (ATR) for slave 10 (second FSSB)
NOTE
After specifying these parameters, turn the power off and
then on again for the new settings to take effect.
.G$8$0.$0?
If the servo control card supporting HIGH SPEED HRV control is to be used, these
parameters must be specified in addition to conventional FSSB setup parameters.
If the FSSB setup mode is automatic setting (bit 0 of parameter No. 1090 is 0),
these parameters are automatically specified. Be sure to specify the parameters if
the mode is manual setting (bit 0 of parameter no. 1090 is 1).
Set the address translation table values for slaves 1 to 10 of the second FSSB.
For details of the settings and restrictions, see the description of parameters Nos.
1080 to 1089.