B-63323EN-1/03 5.AUTOMATIC OPERATION
- 531 -
NOTE
1 Before the completion signal of an M code for non-
buffering is returned, an absolute switch signal
selection must be made, and MIGET must be set to
1.
2 In the reset state or initial automatic operation state,
the MIGET signal must be set to 0.
3 When manual intervention amount regain request
signal is set to 1, a PS059 alarm is issued if there is
a block already buffered (that is, if an M code for
non-buffering is not being executed).
Manual intervention amount regain completion signal
MIFIN <F46#3>
[Classification] Output signal
[Function] Reports that manual intervention amount regain processing during
automatic operation has been completed.
[Output condition] This signal is set to 1 when manual intervention amount regain
processing based on manual intervention amount regain request signal
MIGET is completed. Then, this signal is set to 0 upon confirmation of
the manual intervention amount regain request signal MIGET being set
to 0.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G064 MIGET
#7 #6 #5 #4 #3 #2 #1 #0
F064 MIFIN
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
2409 ABS
# 3 ABS After manual intervention by manual absolute on, this bit specifies
whether the travel command path for absolute (G90) and for
incremental (G91) are the same.
0: Different
1: Same (path for absolute)