2.PREAPARATIONS FOR OPERATION B-63323EN-1/03
- 330 -
Jog feed selection signal
J <G003#2>
[Classification] Input signal
[Function] Selects jog feed mode.
Manual operation such as jog feed, manual reference position return,
and manual numeric value specification is performed.
[Operation] See "Operation mode selection method" and "Operation at the time of
operation mode switching," above.
Increment feed selection signal
S <G003#0>
[Classification] Input signal
[Function] Selects incremental feed mode. Incremental feed is performed.
[Operation] See "Operation mode selection method" and "Operation at the time of
operation mode switching," above.
Manual handle feed selection signal
H <G003#1>
[Classification] Input signal
[Function] Selects manual handle feed mode. Manual handle feed is performed.
[Operation] See "Operation mode selection method" and "Operation at the time of
operation mode switching," above.
Manual arbitrary-direction feed selection signal
AGJ <G003#7>
[Classification] Input signal
[Function] Selects manual arbitrary-direction feed mode. Manual arbitrary-
direction feed is performed.
[Operation] See "Operation mode selection method" and "Operation at the time of
operation mode switching," above.
Simultaneous automatic and manual operation selection signal
MOVL <G002#4>
[Classification] Input signal
[Function] Selects simultaneous automatic and manual mode. The operation mode
being applied in each of automatic operation mode and manual
operation mode depends on the mode selection signal settings.
[Operation] See "Operation mode selection method" and "Operation at the time of
operation mode switching," above.
Manual data input selection confirmation signal
MD <F003#3>
[Classification] Output signal
[Function] Indicates that manual data input mode is selected.
[Output condition] See "Operation mode selection method" and "Operation at the time of
operation mode switching," above.