1.AXIS CONTROL B-63323EN-1/03
- 40 -
5424 Interval of pitch error compensation points for each axis
NOTE
After this parameter has been set, the power must be off turned off
then back on for the setting to become effective.
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] See the following descriptions.
Pitch error compensation points are set at regular intervals. Set
this interval for each axis.
The minimum interval of pitch error compensation points is
determined from the following equation:
Minimum interval = maximum feedrate/7500
Unit
mm, inch, deg or mm, min, inch, min, deg
min
Example: When the maximum feedrate is 15000 mm/min, the
minimum interval of pitch error compensation points is 2 mm.