B-63323EN-1/03 7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL
- 617 -
7.1.1 Rapid Traverse Rate
Overview
The positioning command (G00) positions the tool by rapid traverse.
G00 IP_ ;
G00 : G code (group 01) for positioning (rapid traverse)
IP_ ; Dimension word for the end point
With rapid traverse, the system waits for the specified feedrate to fall to
zero, then performs the in-position check set for parameter CIP (bit 0 of
No. 1000). The system then executes the next block.
A rapid traverse rate is set for each axis by parameter No. 1420, so no
rapid traverse rate need be programmed.
The following overrides can be applied to a rapid traverse rate with the
rapid traverse override signal:F0, F1, 50, 100%
F0 : Allows a fixed feedrate to be set for each axis by parameter
No. 1421.
F1 : Constant percentage, which can be set for parameter No.
1412.
By setting parameter ROV (bit 0 of No. 1402), a rapid traverse override
of 0 to 100% can be applied, in 1% steps.
(For an explanation of the rapid traverse override, see Section 7.1.7.1.)
Signal
Rapid traversing signal RPD<F001#5>
[Function] This signal indicates that a move command is executed at rapid
traverse.
[Output condition] "1" indicates that an axis starts moving after
rapid traverse has been selected.
"0" indicates that an axis starts moving after a feedrate other than rapid
traverse has been selected. This holds true for both automatic and
manual operation modes.