7.UNITS B-70315EN/02
- 184 -
(c) Function code setting method
(A029 is displayed.)
Press the key.
The code No. of the monitor mode, basic setting mode, or extended function monitor can be directly entered instead of
using the scroll method.
n example of changing from monitor mode code No. d001 to function code No. A029 is indicated below.
<1> The code No. of the monitor mode is
displayed. (d001 is displayed.)
<6> The setting of the function code
No. is completed.
Press the and
key at the same time.
"9" in the ones digit position blinks.
("9" is set.)
Press the key (2
times) or press the
key (8 times).
The setting of A029 is completed.
Note) If a code No. not listed in the
code table is entered, "A" at
the left end blinks again.
Check the code No. and enter
a correct value.
<2> Extended function mode change
<5> Change the ones digit of the
function code No..
"d" blinks.
"1" in the ones digit position blinks.
Press the key (2
times).
(A001 is displayed.)
Press the key.
(A021 is displayed.)
"A" blinks
Pressing the
key sets the value of the
blinking digit position.
"2" in the tens digit position blinks.
Press the key (to
set "A".)
Press the key (2
times).
<3> Change the hundreds digit of
the function code No..
<4> Change the tens digit of the
function code No..
Press the
key.
("0" is set.)
"0" in the hundreds digit position blinks.
"0" in this position is not changed. So,
ust press the key to set 0.
"0" in the tens digit position blinks.