B-70315EN/02 APPENDIX E.PARAMETER LIST
- 301 -
#7 #6 #5 #4 #3 #2 #1 #0
15011 OPV ST2 CSC LVE EDS
[Data type] Bit
EDS
0: Uses the conventional conditions as the cutting conditions during
execution of edge machining or start-up processing for a return.
1: Uses the piercing operating conditions in edge machining for the
laser power, assist gas type, and assist gas pressure as cutting
conditions during execution of edge machining or start-up
processing for a return.
This setting has priority over the setting of bit 3 of parameter No.
15011.
LVE
0: Performs assist gas switching according to the conventional
specifications at the start of edge machining and at the start of
cutting for the return distance after that.
1: Ignores the time setting when the gas type and pressure do not
change for assist gas switching at the start of edge machining and
at the start of cutting for the return distance after that.
This setting is invalid when bit 0 of parameter No. 15011 is set to 1.
CSC When the following four values, S, P, Q, and F, are concurrently
specified in the first G01, G02, or G03 block following G24 in the
start-up processing mode,
0: Executes conventional start-up processing without using the
specified S, P, Q, and F values.
1: Cancels operation of start-up processing and performs cutting
using the specified S, P, Q, and F values.
ST2 The operation of the step function is based on:
0: Conventional specifications.
1: New specifications.
OPV
0: The external piping exhaust valve operates only once after
power-on. (conventional)
1: The external piping exhaust valve always operates when RUN is
turned on.
#7 #6 #5 #4 #3 #2 #1 #0
15012 CVA
[Data type] Bit
CVA Angle determination for the edge machining function:
0: Follows the setting of bit 3 (ECK) of parameter No. 15007.
1: Does not follow the setting of bit 3 (ECK) of parameter No.
15007, but is performed based on the programmed path.