B-70315EN/02 7.UNITS
- 189 -
Code Name of function
Initial
value
Setting
value
Remarks
b034 Run time/power ON time level 0hr 0hr
0. to 9999.(0 to 99990hr)/1000 to 6553(100000 to 655300)hr
b035 Operation direction limitation selection 00 02
00: Forward and reverse rotation enabled, 01: Forward
rotation only enabled, 02: Reverse rotation only enabled
b036 Reduced-voltage start selection 06 06
00: Short reduced-voltage start time to 06: Long
reduced-voltage start time
b037 Display selection 00 00
00: All data displayed, 01: Function-by-function display, 02:
User setting/this setting
b080 AM adjustment 180 180
0 to 255
b081 FM adjustment 60 60
0 to 255
b082 Start frequency 0.50Hz 0.50Hz
0.10 to 9.99
b083 Carrier frequency 5.0kHz 5.0kHz
0.5 to 10.0 derating applicable
b084 Initialization selection 00 00
00: Trip history clear, 01: Data initialization, 02: Trip history
data clear + data initialization
b085 Initialization data selection 00 00
00: Domestic, 01: CE, 02: USA
b086 Frequency conversion factor 1.0 1.0
0.1 to 9.99
b087 Stop key selection 00 01
00: Enabled, 01: Disabled
b088 Free run stop selection 00 00
00: 0 Hz start, 01: f-matched start, 02: Start at frequency
immediately before free run
b090 BRD use ratio 0.0% 0.0%
0.0 to 100.0
b091 Stop time selection 00 00
00: Deceleration ? stop, 01: Free run stop
b092 Cooling fan operation selection 00 01
00: At all times, 01: During operation only (including 5 minutes
after power-on and stop)
b095 BRD selection 00 00
00: Disabled, 01: Enabled (disabled during stop), 02: Enabled
(enabled even during stop)
b096 BRD on level 360/720V 360/720V
330 to 380 / 660 to 760
b098 Thermistor selection 00 00
00: Disabled, 01: PTC, 02: NTC enabled
b099 Thermistor error level
3000Ω 3000Ω
0 to 9999
C061 Thermal warning level 80% 80%
0 to 100
C091 Debug mode selection 00 00
00: Not displayed, 01: Displayed
C101 Up/down selection 00 00
00: Frequency data not saved, 01: Frequency data saved
C102 Reset selection 00 00
00: Trip released when ON, 01: Trip released when OFF, 02:
Enabled only at trip time (released when ON)
C103 Reset selection f-matched selection 00 00
00: 0 Hz start, 01: f-matched start
C121 0 zero adjustment
Factory-
adjusted
Factory-
adjusted
C122 01 zero adjustment
Factory-
adjusted
Factory-
adjusted
C123 02 zero adjustment
Factory-
adjusted
Factory-
adjusted
H003 First motor capacity selection
Factory-
adjusted
5.5 (11)
H203 Second motor capacity selection
Factory-
adjusted
Factory-
adjusted
H004 First motor pole count selection 4 2
H204 Second motor pole count selection 4 4
2, 4, 6, 8
H006 First stabilizer constant 100 100
H206 Second stabilizer constant 100 100
0 to 255
P001 Option 1 error time operation selection 00 00
P002 Option 2 error time operation selection 00 00
00:TRP, 01:RUN
Others
U001
to
U012
User 1 selection
to
User 12 selection
no no
no. d001 to P002
NOTE
The settings enclosed in parentheses ( ) are for
the inverter for driving two units.