B-70315EN/02 7.UNITS
- 185 -
(d) Parameter settings
Code Name of function
Initial
value
Setting
value
Remarks
d001 Output frequency monitor - -
Hz
d002 Output current monitor - -
A
d003 Rotation direction monitor - -
F (forward rotation)/o (stop)/r (reverse rotation)
d004 PID feedback monitor - -
d005 Intelligent input monitor - -
d006 Intelligent output monitor - -
d007 Frequency conversion monitor - -
d013 Output voltage monitor - -
V
d014 Input power monitor - -
kW
d016 Cumulative run time monitor - -
d017 Power ON time monitor - -
hr
d080 Trip count monitor - -
Times
d081 Trip monitor 1 - -
d082 Trip monitor 2 - -
d083 Trip monitor 3 - -
d084 Trip monitor 4 - -
d085 Trip monitor 5 - -
d086 Trip monitor 6 - -
Cause, frequency (Hz), current (A), voltage (V), run time (hr),
power ON time (hr)
d090 Warning monitor - -
F001 Output frequency 0.00Hz 1000
0.0, start frequency to maximum frequency
F002 First acceleration time setting 30.00s 70
F202 Second acceleration time setting 30.00s 30.00s
F003 First deceleration time setting 30.00s 70
F203 Second deceleration time setting 30.00s 30.00s
0.01 to 3600
Monitor
mode
F004 Operation direction selection 00 01
00: Forward rotation, 01: Reverse rotation
A001 Frequency command selection 02 02
00: VR, 01: Terminal, 02: Operator, 03: RS485, 04: Option 1,
05: Option 2
A002 Operation command selection 02 01
01: Terminal, 02: Operator, 03: RS485, 04: Option 1, 05:
Option 2
A003 First base frequency 1000Hz 1000Hz
30 to maximum frequency
A203 Second base frequency 1000Hz 1000Hz
30 to second maximum control frequency
A004 First maximum frequency 1000Hz 1000Hz
Basic
setting
A204 Second maximum frequency 1000Hz 1000Hz
30 to 1500
A005 AT terminal selection 00 00
00: Switched between and 0 and 01 on AT terminal, 01:
Switched between 0 and 02 on AT terminal
A006 02 selection 00 00
00: Single, 01: 0 and 01 auxiliary speed (with no reversing),
02: 0 and 01 auxiliary speed (with reversing)
A011 0 start 0.00Hz 0.00Hz
A012 0 end 0.00Hz 0.00Hz
0.00 to 1500
A013 0 start ratio 0% 0%
A014 0 end ratio 100% 100%
0 to 100
A015 0 start selection 01 01
00: External start frequency, 01: 0 Hz
Analog
input
A016 0, 01, 02 filter 8 times 8 times
1 to 30
A019 Multistage speed, jogging 00 00
00: Binary (settable up to 16 stages of speed with 4 terminals),
01: Bit (settable up to 8 stages of speed with 7 terminals)
A020 First multistage speed 0 0.00Hz 1000
0.00, start frequency to maximum frequency (The value of
F001 is automatically entered.)
A220 Second multistage speed 0 0.00Hz 0.00Hz
0.00, start frequency to second maximum control frequency
A021 Multistage speed 1 0.00Hz 0.00Hz
A022 Multistage speed 2 0.00Hz 0.00Hz
A023 Multistage speed 3 0.00Hz 0.00Hz
A024 Multistage speed 4 0.00Hz 0.00Hz
A025 Multistage speed 5 0.00Hz 0.00Hz
A026 Multistage speed 6 0.00Hz 0.00Hz
A027 Multistage speed 7 0.00Hz 0.00Hz
A028 Multistage speed 8 0.00Hz 0.00Hz
A029 Multistage speed 9 0.00Hz 0.00Hz
A030 Multistage speed 10 0.00Hz 0.00Hz
A031 Multistage speed 11 0.00Hz 0.00Hz
A032 Multistage speed 12 0.00Hz 0.00Hz
A033 Multistage speed 13 0.00Hz 0.00Hz
A034 Multistage speed 14 0.00Hz 0.00Hz
A035 Multistage speed 15 0.00Hz 0.00Hz
0.00, start frequency to maximum frequency
Multistage
speed
selection
A038 Jogging frequency 1.00Hz 1.00Hz
0.00, start frequency to 9.99