E.PARAMETER LIST APPENDIX B-70315EN/02
- 320 -
15206 Time constant for the power sensor input filter
[Data type] Word
[Unit of data] msec
[Valid data range] 8 to 32767
This time constant is used when the laser power monitor value input
from the power sensor is multiplied by the primary delay filter.
15207 Maximum specifiable power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
If the power setting after power compensation or power feedback
addition exceeds this value, the power output is clamped to this value.
15208 Laser power feedback gain
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
Set the laser power feedback gain.
15209 Power feedback clamp
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
This clamp value is used to prevent the excess power setting from
being made during power feedback.
15210 Maximum command power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
This is power clamp when power command is greater than this value.
15211 Minimum command power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
This is power clamp when power command is smaller than this value.