B-70315EN/02 7.UNITS
- 199 -
• Setting in the pressure setting mode
Perform operating pressure setting for the sensor. Note that
different values are set for the gas supply pressure sensor and
atmospheric pressure sensor.
List of settings (Unit: MPa)
Gas supply pressure
sensor (PSW1)
Atmospheric pressure sensor
(PSW2)
P1 0.050 0.000
P2 0.045 -0.005
P3 0.200 0.100
P4 0.200 0.100
Set 0.200 by pressing and .
Set 0.200 by pressing and .
Press the SET key.
P_2 and a number are displayed
alternately.
Set 0.045 by pressing and .
Set 0.050 by pressing and .
Press the SET key.
Press the SET key.
Press the SET key.
Measurement mode
P_1 and a number are displayed
alternately.
Settings for the gas supply pressure
sensor (PSW1)
Set 0.100 by pressing and .
Set -0.005 by pressing and .
Set 0.000 by pressing and .
Set 0.100 by pressing and .
Settings for the atmospheric
pressure sensor (PSW2)
In the measurement mode, hold down the
SET key for less than 2 seconds.
P_3 and a number are displayed
alternately.
P_4 and a number are displayed
alternatel
.