B-70315EN/02 APPENDIX E.PARAMETER LIST
- 323 -
E.11 PARAMETERS FOR DISCHARGE
15220 Discharge start command value
[Data type] Word
[Unit of data] mV
[Valid data range] 0 to 32767
Set a command value to start discharge.
15221 Discharge start decision voltage
[Data type] Word
[Unit of data] V
[Valid data range] 0 to 32767
If the discharge tube voltage is lower than the specified value after the
elapse of the discharge waiting time, it is assumed that discharge has
started.
15222 Discharge waiting time
[Data type] Word
[Unit of data] 10msec
[Valid data range] 0 to 32767
Set a wait time after the specification of the start of discharge until the
discharge start command value is set.
15223 Bias command
[Data type] Word
[Unit of data] mV
[Valid data range] 0 to 32767
Set a bias command value for the oscillation preparation completion
state (LSTR).
15224 Modulation voltage
[Data type] Word
[Unit of data] mV
[Valid data range] 0 to 3000
Set the voltage to which the normal bias value is lowered during
modulation by the base modulation function.
15225 Modulation time
[Data type] Word
[Unit of data] 10msec
[Valid data range] 0 to 32767
Set a time required usually to decrease the bias value with the base
modulation function at the time of modulation.