B-70315EN/02 APPENDIX E.PARAMETER LIST
- 315 -
15120 Processing flow pressure 1
15121 Processing flow pressure 2
15122 Processing flow pressure 3
[Data type] Word
[Unit of data] 0.01MPa or 0.1 kg/cm
2
[Valid data range] 0 to 255
Set the assist gas processing flow pressure.
15126 After flow pressure 1
15127 After flow pressure 2
15128 After flow pressure 3
[Data type] Word
[Unit of data] 0.01MPa or 0.1 kg/cm
2
[Valid data range] 0 to 255
Set the assist gas after-flow pressure.
15132 Maximum assist gas pressure
[Data type] Word
[Unit of data] 0.01MPa or 0.1 kg/cm
2
[Valid data range] 0 to 255
Set an assist gas pressure (kg/cm
2
(MPa)) at which 10V is output in
analog output.
15135 Assist gas pressure set time
[Data type] Word
[Unit of data] 10msec
[Valid data range] 0 to 32767
Set a desired assist gas pressure set time.
15136 Assist gas pressure
[Data type] Word
[Unit of data] 0.01MPa or 0.1 kg/cm
2
[Valid data range] 0 to 255
Set a desired assist gas pressure.
15137 Assist gas pressure set time for piercing
[Data type] Word
[Unit of data] 10msec
[Valid data range] 0 to 32767
Set a desired assist gas pressure set time for piercing.