B-70315EN/02 APPENDIX E.PARAMETER LIST
- 327 -
15256 RUN OFF evacuation time
[Data type] Word
[Unit of data] sec
[Valid data range] 600 to 32767
When bit 2 of parameter No. 15003 (GVW) is set 1 and the oscillator
start signal (G222#6 RUN) is set to "0," evacuation is performed
according to this time setting.
15257 Number of abnormal vibrations detected
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767
If the number of abnormal vibrations (per 10 minutes) detected
exceeds the value specified in this parameter, an alarm is issued.
15258 Time constant of the filter used for laser gas pressure variation suppression
[Data type] Word
[Unit of data] msec
[Valid data range] 17to 32767 (If a value less than 16 is specified, the filter does not
function.)
15259 Exhaust time when RUN is ON
[Data type] Word
[Unit of data] sec
[Valid data range] 0 to 32767
Set an exhaust time to be applied at oscillator start time (RUN).
15260 Period when the exhaust value of the external pipe is open
[Data type] Byte
[Unit of data] sec
[Valid data range] 0 to 60 (When a time beyond 60 sec is specified, the time is clamped
to 60 sec.)
Set the time the exhaust valve of the external pipe is open.