FANUC Power Mate i - MODEL D/H
Addition of custom macro interface signal
TITLE
Replace the “Signal” of “11.3.1 Custom macro” with the following description
Custom macro input signal
UI000~UI031
<G054~G057>
UI100~UI131
<G276~G279>
UI200~UI231
<G280~G283>
UI300~UI331
<G284~G287>
[classificiation]input signal
[function]No function is provided for the control unit. These signals can be read by a custom macro
as a type of system valiable, and are used for interface signals between custom macro and the
PMC.
These signals correspond to the system valiable as follows.
A parameter No.6001#0(MIF)=”0” A parameter No.6001#0(MIF)=”1” Signals
Q’ty Valiables Q’ty Valiables
Correspondence of
value
UI000
UI001
UI002
:
UI014
UI015
UI016
:
UI030
UI031
1
1
1
:
1
1
#1000
#1001
#1002
:
#1014
#1015
1
1
1
:
1
1
1
:
1
1
#1000
#1001
#1002
:
#1014
#1015
#1016
:
#1030
#1031
0 at “0” and
1 at “1”
UI000~UI015 16 #1032 16bit binary code “1” *1
UI000~UI031
UI100~UI131
UI200~UI231
UI300~UI331
32
32
32
32
#1032
#1033
#1034
#1035
32bit binary code “1” *2
15
*1 : Valiable value #1032 = Σ{#[ 1000+i ]×2
i
}
i=0
30
*2 : Valiable value #1032 #1033, #1034, #1035 = Σ{2
i
×V
i
} - 2
31
×V
31
i=0
Where V
i
=0 when UI0i, UI1i, UI2i, UI3i (i:0 to 31) is ”0”,
V
i
=1 when UI0i, UI1i, UI2i, UI3i (i:0 to 31) is ”1”
Note)When a paramter No.6001#0(MIF) is set 1, input signal to extend is effective by using PMC-SB6.
B-63173EN-1/01-34
2 / 9
EDIT
DATE DESIG. DESCRIPTION
DRAW.NO.
CUST.
SHEET
01 02/05/16 New design