B–63173EN–1/01
15. PMC CONTROL FUNCTION
541
#7
2000
#6 #5 #4 #3 #2 #1
DGPRx
#0
[Data type] Bit axis
DGPRx At power–ON, the torque constant (parameter No. 2105):
0 : Is automatically set to the standard value specific to the motor.
1 : Is not automatically set to the standard value specific to the motor.
#7
TRQx2007
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit axis
TRQx Torque control:
0 : Is not performed for the axis.
1 : Is performed for the axis.
2105 Torque constant
[Data type] Word axis
[Unit of data] 0.00001 Nm/(torque command)
[Valid data range] 1 to 32767
A torque constant is set for each motor torque characteristic.
NOTE
When a linear motor is used, the units of data are 0.001
N/(torque command).
#7
3105
#6 #5 #4 #3 #2 #1
PCF
#0
[Data type] Bit
PCF Whether movement along PMC–controlled axes is included in the actual
speed display
0 : Included
1 : Not included
NOTE
This parameter is valid when the same axis is controlled