B–63173EN–1/01
1. AXIS CONTROL
54
1910 Address conversion table value for slave 1 (ATR)
1911 Address conversion table value for slave 2 (ATR)
1912 Address conversion table value for slave 3 (ATR)
1913 Address conversion table value for slave 4 (ATR)
1914 Address conversion table value for slave 5 (ATR)
1915 Address conversion table value for slave 6 (ATR)
1916 Address conversion table value for slave 7 (ATR)
1917 Address conversion table value for slave 8 (ATR)
1918 Address conversion table value for slave 9 (ATR)
1919 Address conversion table value for slave 10 (ATR)
[Data type] Byte
[Valid data range] 0 to 7, 16, 40, and 48
An address conversion table value must be specified for each of slaves 1
to 10. The term “slave” refers to any of the servo amplifiers and pulse
modules connected to the CNC. Each slave is assigned a number of
between 1 and 10 sequentially, with the one nearest to the CNC assigned
number 1. A two–axis amplifier is regarded as being two slaves, while
a three–axis amplifier is regarded as being three slaves. Each of these
parameters is set depending on whether the slave is an amplifier or pulse
module, as follows:
f When the slave is an amplifier:
The parameter is set to the “value in parameter No. 1023 for an axis
to which the amplifier is assigned,” minus 1.
f When the slave is a pulse module:
The parameter is set to 16 for the first pulse module (that nearest to the
CNC) or to 48 for the second pulse module (that farthest from the
CNC).
f When there is no slave:
The parameter is set to 40.
If automatic setting is set as the FSSB setting mode (bit 0 of parameter
No. 1902 = 0), this parameter is set automatically when data is entered on
the FSSB setting screen. For manual setting 2 (bit 0 of parameter No.
1902 = 1), the parameter must be set manually.