4. REFERENCE POSITION ESTABLISHMENT
B–63173EN–1/01
178
#7
1002
#6 #5 #4 #3 #2 #1
DLZ
#0
JAX
[Data type] Bit
JAX Number of axes controlled simultaneously in manual continuous feed,
manual rapid traverse and manual reference position return
0 : 1 axis
1 : 2 axes (3 axes for Power Mate i–H)
DLZ Function setting the reference position without dog
0 : Disabled
1 : Enabled
NOTE
This function can be specified for each axis by DLZx, bit 1
of parameter No. 1005.
#7
1005
#6 #5 #4 #3 #2 #1
DLZx
#0
ZRNx
[Data type] Bit axis
ZRNx When a command specifying the movement except for G28 is issued in
automatic operation (AUTO, RMT, or MDI) and when a return to the
reference position has not been performed since the power was turned on
0 : An alarm is generated (P/S alarm 224).
1 : An alarm is not generated.
DLZx Function for setting the reference position without dogs
0 : Disabled
1 : Enabled
NOTE
When DLZ of parameter No. 1002#1 is 0, DLZx is enabled.
When DLZ of parameter No. 1002#1 is 1, DLZx is disabled,
and the function for setting the reference position without
dogs is enabled for all axes.
#7
1006
#6 #5
ZMIx
#4 #3 #2 #1 #0
NOTE
When this parameter is changed, turn off the power before
continuing operation.
[Data type] Bit axis
Parameter