FANUC LTD
11/12
CUST.
SHEET
TITLE
DRAW.NO.
FANUC Power Mate i-MODEL H
High-speed skip function (with traveling
distance from skip signal) in PMC axis control
B-63173EN-1/01-23
01
[Data type]
[Data type][Data type]
[Data type]
Bit type
EPMCn The signal DI3n (X1003 bit n) is
0: used for high-speed skip function or measuring
function by using high-speed skip signal
1: used for interrupt type PMC
[Data type]
[Data type][Data type]
[Data type]
Bit type
UPEGn The rising edge (0 --> 1) of the signal DI3n (X1003 bit n) is :
0: not used for interrupt type PMC or high-speed skip signal.
1: used for interrupt type PMC or high-speed skip signal.
[Data type]
[Data type][Data type]
[Data type]
Bit type
DWEGn The falling edge (1 --> 0) of the signal DI3n (X1003 bit n) is
0 : not used for interrupt type PMC or high-speed skip signal
1 : used for interrupt type PMC or high-speed skip signal.
#7 #6 #5 #4 #3 #2 #1 #0
8731
EPMC7 EPMC6 EPMC5 EPMC4 EPMC3 EPMC2 EPMC1 EPMC0
Note
NoteNote
Note
This parameter must be set to 0, when the above functions are not
This parameter must be set to 0, when the above functions are notThis parameter must be set to 0, when the above functions are not
This parameter must be set to 0, when the above functions are not
used.
used.used.
used.
#7 #6 #5 #4 #3 #2 #1 #0
8732
UPEG7 UPEG6 UPEG5 UPEG4 UPEG3 UPEG2 UPEG1 UPEG0
#7 #6 #5 #4 #3 #2 #1 #0
8733
DWED7 DWED6 DWED5 DWED4 DWED3 DWED2 DWED1 DWED0