12. DISPLAY/SET/EDIT
B–63173EN–1/01
448
6750 Integrated value of power–on period
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter displays the integrated value of power–on period.
6751 Operation time (integrated value of time during automatic operation)
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One ms
[Valid data range] 0 to 60000
6752 Operation time (integrated value of time during automatic operation)
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter displays the integrated value of time during automatic
operation (neither stop nor hold time included).
The actual operation time is the sum of the values set in parameter Nos.
6751 and 6752.
6753 Integrated value of cutting time
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One ms
[Valid data range] 1 to 60000
6754 Integrated value of cutting time
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter displays the integrated value of a cutting time that is
performed in cutting feed such as linear interpolation (G01) and circular
interpolation (G02 or G03).
The actual cutting time is the sum of the values set in parameter Nos. 6753
and 6754.