B–63173EN–1/01
1. AXIS CONTROL
56
1920 Controlled axis number for slave 1 (FSSB setting screen only)
1921 Controlled axis number for slave 2 (FSSB setting screen only)
1922 Controlled axis number for slave 3 (FSSB setting screen only)
1923 Controlled axis number for slave 4 (FSSB setting screen only)
1924 Controlled axis number for slave 5 (FSSB setting screen only)
1925 Controlled axis number for slave 6 (FSSB setting screen only)
1926 Controlled axis number for slave 7 (FSSB setting screen only)
1927 Controlled axis number for slave 8 (FSSB setting screen only)
1928 Controlled axis number for slave 9 (FSSB setting screen only)
1929 Controlled axis number for slave 10 (FSSB setting screen only)
[Data type] Byte
[Valid data range] 0 to 8
Each of these parameters is set using a controlled axis number for a slave
numbered 1 to 10. This parameter is set automatically when data is
entered using the FSSB setting screen; do not specify it manually. For
manual setting 2, the parameter need not be set.
1931 Connector number for first pulse module (FSSB setting screen only)
1932 Connector number for second pulse module (FSSB setting screen only)
[Data type] Byte axis
[Valid data range] 0 to the number of connectors in each pulse module
To use a pulse module, the user must specify a connector number for the
pulse module on each axis. This parameter is set automatically when data
is entered using the FSSB setting screen; do not specify it manually. For
manual setting 2, the parameter need not be set.
1934 Master/slave number for tandem–controlled axes (FSSB setting screen only)
[Data type] Byte axis
[Valid data range] 0 to 8
To use tandem control, this parameter must be set to an odd number (for
the master axis) or to an even number (slave axis). This parameter is set
automatically when data is entered using the FSSB setting screen; do not
specify it manually. For manual setting 2, the parameter need not be set.