5/16
EDIT
DATE
DESIG.
DESCRIPTION
CUST.
SHEET
TITLE
DRAW.NO.
FANUC Power Mate i-MODEL H
CONNECTION MANUAL(FUNCTION)
Custom Macro in the high response mode
B-63173EN-1/01-27
1024 This error occurs when one of the following commands is specified.
• The macro variable ‘#’ is specified for M code group number.
Example) 50 P#1000000 ;;
• The macro variable ‘#’ is specified for the parameter of the M
code output function.
Example) 40 P#1000000 Q1 ;;
1030 The macro sentence is not available because of the parameter setting.
1060 The operator for the arithmetic or logic operation (=) is not correct.
Example) #1000000 = #1000000 ABS[#1200000] ; ;
1061 The number of the sequence number in a program is 1001 or over.
1062 The number of terms in the right of the operator is 2 or over.
Example) #1000000 = #1200000 + #1200000+ #1200000 ;;
1063 The modal commands are not specified just after the ‘N’ or WHILE
statement.
Example) GOTO 1 ;;
N1 X1000 ;;
Add the following alarm codes in Add the following alarm codes in ““The alarm number at the diagnosis data No.896The alarm number at the diagnosis data No.896”” of of
““22. High response function22. High response function””
Number Contents
0011
The value of the feedrate is 0.
(The value of the macro variable for F#____ is 0.)
0111 The result of calculation is out of the allowable range
0112 Division by zero was specified.
0115 Unavailable variable number is input.
1050 The value of macro variable for G135.3 Q#____ R#_____ is minus.