15. PMC CONTROL FUNCTION
B–63173EN–1/01
532
[Classification] Output signal
[Function] This signal is set to “1” when the feedrate override is 0%.
[Classification] Input signal
[Function] When this signal is set to “1” during executing the skip cutting command,
the block being executed is immediately stopped and the next block is
executed. Bit 7 (SKE) of parameter No. 8001 can be used to select
whether to use signal SKIP, which is the common skip signal for the PMC
and CNC, or PMC–specific skip signal ESKIP.
[Classification] Output signal
[Function] These signals are set to “0” when the tool is moving with a command from
the PMC. The signals are set to “1” when the tool is not moving, except
when it is stopped by the issue of an axis control temporary stop signal
ESTPg during the execution of a move command.
[Classification] Output signal
[Function] This signal is set to “1” when the input buffer contains a command block.
[Classification] Output signal
[Function] When the control axis selection status signal *EAXSL is set to “1”, signal
EACNTn corresponding to the axis being controlled is set to “1”.
29 Override 0% signal
EOV0
30 Skip signal ESKIP
31 Distribution
completion signals
EADEN1 to EADEN8
32 Buffer full signal
EABUFg
33 Controlling signals
EACNT1 to EACNT8