B–63173EN–1/01
1. AXIS CONTROL
71
#7 #6 #5 #4 #3 #2 #1 #0
SMF3105
[Data type] Bit
SMF During simple synchronous contorol, movement along a slave axis is:
0 : Included in the actual speed display
1 : Not included in the actual speed display
NOTE
This parameter is valid when simple syncronous contorol is
applied according to the setting of parameter No. 8311
(master and slave axes can be arbitrarily selected).
#7 #6 #5 #4 #3 #2 #1 #0
SOF8301
[Data type] Bit
SOF The synchronization compensation funciton under simple synchronous
control (one master/slave axis pair) is:
0 : Not used.
1 : Used.
#7
8302
#6 #5 #4 #3 #2 #1
ATS
#0
ATE
NOTE
The system power must be turned off then back on in order
for this parameter setting to become effective.
[Data type] Bit
ATE Specify whether to enable the automatic setting of grid positioning under
simple synchronous control (one master/slave axis pair)
0 : Disabled
1 : Enabled
ATS Specify whether to start the automatic setting of grid positioning under
simple synchronous control (one master/slave axis pair)
0 : Not started
1 : Started
NOTE
1 Setting this parameter resets parameter APZx (bit 4 of
parameter No. 1815) for the master and slave axes and
parameter No. 8316 to 0.
2 This parameter automatically becomes 0 upon the
completion of grid positioning.
Parameter