4. SERVO FUNCTION DETAILS B-65150E/04
− 100 −
Table 4.2 OVC parameters
Conventional setting (standard) Setting for improvement
ID No. MOTOR
POVC1 POVC2 POVCLMT POVC1 POVC2 POVCLMT
68
αL3
32693 940 2787 32740 345 2048
69
αL6
32696 894 2653 32742 329 1949
70
αL9
32607 2010 5970 32709 740 4386
84
α2.5/3000
32569 2482 7376 32695 913 5419
90
1500A
32670 1222 3626 32732 449 2664
91
3000B
32670 1222 3626 32732 449 2664
92
6000A
32670 1222 3626 32732 449 2664
93
9000B
32685 1041 3087 32737 383 2268
94
15000C
32712 703 2086 32740 352 2086
98
αM2
32685 1041 3089 32726 521 3089
99
αM2.5
32645 1535 4556 32707 768 4556
100
αM22
32587 2260 6714 32677 1131 6714
101
αM30
32567 2514 7473 32677 1259 7473
102
α22HV
32590 2221 6599 32679 1112 6599
103
α30HV
32586 2279 6771 32677 1141 6771
104
αM6HV
32725 538 1596 32746 269 1596
105
αM9HV
32678 1119 3321 32723 560 3321
106
αM22HV
32596 2149 6385 32682 1076 6385
107
αM30HV
32447 4009 11935 32607 2009 11935
108
αM40/FAN(360A)
32613 1937 5752 32690 970 5752
110
αM40(130A)
32279 6107 18231 32523 3065 18231
111
α300/2000
32326 5521 16468 32546 2770 16468
112
α400/2000
32299 5861 17492 32533 2941 17492