Correction of Servo Parameter Setting
Description.
B-65150E/04-006
FANUC LTD
Correction of Servo Parameter Setting Description.
2.1.4 (4) Setting parameters
[Before correction]
Parameter No. Remarks
2000#0 1
2023 8192/10/2
2024 160000/10/2
2043 (Value to be set originally)/2
2044 (Value to be set originally)/2
2047 (Value to be set originally)*2
2053 (Value to be set originally)*2
2054 (Value to be set originally)/2
2056 (Value to be set originally)/2
2057 (Value to be set originally)/2
2059 (Value to be set originally)*2
2074
(Remainder of the value to be set originally/4096)/ 2 +
(quotient of the value to be set originally/4096)
×
4096
2076 (Value to be set originally)/2
2128 (Value to be set originally)/2
2129
(Quotient of the value to be set originally/256)
×
2
×
256 +
(remainder of the value to be set originally/256)
[After correction]
Parameter No. Remarks
2000#0 1
2023 8192/10/2
2024 160000/10/2
2043 (Value to be set originally)/2
2044 (Value to be set originally)/2
2047 (Value to be set originally)*2
2053 (Value to be set originally)*2
2054 (Value to be set originally)/2
2056 (Value to be set originally)/2
2059 (Value to be set originally)*2
2076 (Value to be set originally)/2
2128 (Value to be set originally)/2
2129
(Quotient of the value to be set originally/256)
×
2
×
256 +
(remainder of the value to be set originally/256)
[Contents of correction]
Parameters
No.2057 and
No.2074 are deleted from
this table, because these
parameters are NOT
changed in case of using a
separate detector for the
serial interface.