B-65150E/04 5. DETAILS OF PARAMETERS
− 311 −
OVS1 (#3) 1: Overshoot compensation is valid
only once after the termination of a
move command.
⇒ See Sec. 4.7.
DUAL (#4) Zero width is determined:
0: Only by setting = 0
1: By setting
⇒ See Subsec. 4.5.4.
Related parameters:
1974 (Series 15) and 2081
(Series 16)
#7 #6 #5 #4 #3 #2 #1 #0
1743
−
FRC2 1/2PI
2203
−
CRPI (#2) The current loop 1/2PI function is:
⇒ See Subsec. 4.5.7.
0: Not used
1: Used
FRC2 (#4) Torque control type 2 is:
⇒ See Sec. 4.15.
0: Not exercised
1: Exercised
#7 #6 #5 #4 #3 #2 #1 #0
1744
−
ERC0 PGW2
2204
−
PGW2 (#5) Position gain switch type 2 is:
0: Not used
1: Used
⇒ See Subsec. 4.8.1.
Related parameters:
1713 (Series 15) and 2028
(Series 16)
ERC0 (#7) Emergency stop distance reduction
function type 2 is:
⇒ See Subsec. 4.11.2.
0: Not used
1: Used
#7 #6 #5 #4 #3 #2 #1 #0
1745
−
FLDY
2205
−
FLDY (#2) The dummy separate detector function
is:
⇒ See Subsec. 4.9.1.
0: Not used
1: Used
#7 #6 #5 #4 #3 #2 #1 #0
1746
−
HSSR
2206
−
HSSR (#7) High-speed data output to the check
board is:
⇒ See Subsecs. 3.4.1 and 4.5.6.
0: Not performed
1: Performed