4. SERVO FUNCTION DETAILS B-65150E/04
− 234 −
1998
−
Torque constant
2105
−
This parameter is used to specify a motor-specific torque constant. The
units are as follows:
0.00001 Nm/torque command for a rotary motor
0.001 Nm/torque command for a linear motor
When the initial parameter setting function (Sec. 2.1) is used, a
motor-specific value is set automatically.
(b) Setting for torque control type 2
#7 #6 #5 #4 #3 #2 #1 #0
1808
−
PIEN
2007
−
PIEN (#3) The velocity control method to be used is:
0: I-P control
1: P-I control ← To be set
#7 #6 #5 #4 #3 #2 #1 #0
1951
−
FRCAXS
2007
−
FRCAXS (#7) Torque control is:
0: Not exercised
1: Exercised ← To be set
#7 #6 #5 #4 #3 #2 #1 #0
1743
−
FRCAX2
2203
−
FRCAX2 (#4) Torque control type 2 is:
0: Not exercised
1: Exercised ← To be set
(Usually, use type 2.)
1998
−
Torque constant
2105
−
This parameter is used to specify a motor-specific torque constant. The
units are as follows:
0.00001 Nm/torque command for a rotary motor
0.001 Nm/torque command for a linear motor
When the initial parameter setting function (Sec. 2.1) is used, a
motor-specific value is set automatically.