3/5
Descri
tion
Design.
DateEd.
00.10.03
.
o.
.
Ihara Newl
desi
ned
Notice of the update of Digital
Servo Software 90B0 series
B-65150E/04-013
FANUC LTD
Attached 1.
Unexpected disturbance detection performed separately
for cutting and rapid traverse
(1) Overview
Unexpected disturbance detection performed separately for cutting and rapid traverse was
made so that an alarm level can be set separately for cutting and rapid traverse. But if
No.1800#3 is set to 1 to make feed-forward function also valid for rapid traverse, it is
impossible to change the alarm level and the alarm level for cutting is always used.
So we report that we have improved the function so as to change the alarm level even
though No.1800#3 is set to 1.
(2) Series and editions of applicable servo software
Series 90A0/X (24) or later (Series 15
i
, 16
i
, 18
i
)
Series 90B0/C (03) or later (Series 15
i
, 16
i
, 18
i
)
(3) Setting parameters
a) Please set the following parameters at first to use the unexpected disturbance
detection performed separately for cutting and rapid traverse.
#7 #6 #5 #4 #3 #2 #1 #0
1740 (FS15
i
)ABG0
2200 (FS16
i
)
ABG0(#3) 1: Enable unexpected disturbance detection performed
separately for cutting and rapid traverse.
Alarm level for unexpected disturbance detection are the following parameters.
1997 (FS15
i
) Unexpected disturbance detection alarm level for cutting (ABTSH)
2104 (FS16
i
)
[Valid data range] 0 - 7282
1765 (FS15
i
)
2142 (FS16
i
)
Unexpected disturbance detection alarm level for rapid traverse
(ABTSHG0)
[Valid data range] 0 - 7282