B-65150E/04 5. DETAILS OF PARAMETERS
− 305 −
#7 #6 #5 #4 #3 #2 #1 #0
1953
−
BLST BLCU ADBL IQOB SERD
2009 1009
SERD (#0) The dummy serial feedback function is:
⇒ See Subsec. 4.9.1.
0: Not used
1: Used
IQOB(#1) 1: Eliminates the effect of voltage
saturation in unexpected disturbance
detection.
This bit functions with the Series 9066
only. With other series, setting bit 2 of
parameter No. 2200 has the same effect.
With the Series 9066, set either bit.
⇒ See Subsec. 4.12.1.
ADBL (#2) The new backlash acceleration function
is:
0: Not used
1: Used
Related parameters:
1860 (Series 15), 2048
(Series 16), 1048 (Power
Mate-E), 1980 (Series 15),
2087 (Series 16), and 1087
(Power Mate-E)
BLCU(#6) The function that validates the backlash
acceleration function only at cutting is:
⇒ See Subsecs. 4.6.4 and 4.6.5.
0: Invalidated
1: Validated
BLST (#7) The backlash acceleration stop function
is:
0: Not used
1: Used
⇒ See Subsec. 4.6.4.
Related parameters:
1975 (Series 15), 2082
(Series 16), and 1082 (Power
Mate-E)
#7 #6 #5 #4 #3 #2 #1 #0
1954
−
POLE HBBL HBPE BLTE LINE
2010 1010
LINE (#2) 1: Controls a linear motor.
This bit is set automatically when the
parameters of the linear motor are
initialized. Check that this bit is set
before the linear motor is driven.
This bit is not supported by the Power
Mate-E.
⇒ See Subsec. 4.14.1.
BLTE (#3) The function to multiply the backlash
acceleration amount by 10 is:
⇒ See Subsecs. 4.6.2 and 4.6.4.
0: Invalidated
1: Validated
HBPE (#4) A pitch error compensation is added to
the error counter of:
⇒ See Subsec. 4.5.4.
0: Full-closed loop ← Standard setting
1: Semi-closed loop