B-65150E/04 4. SERVO FUNCTION DETAILS
− 155 −
1975
−
Stage 2 start/end parameter (detection unit)
2082
−
[Unit of data] Detection unit
[Typical setting] 10 (For a detection unit of 1
µm)
100 (For a detection unit of 0.1
µm)
1982
−
Stage 2 end scale factor
2089
−
[Unit of data] In units of 0.1
[Valid data range] 0 to 647 (multiplication by 0 to 64.7)
Normally, this value may be set to 0.
If parameter No. 1982 (Series 15) or No. 2089 (Series 16) is set to 0, the
start of stage 2 acceleration is determined by the absolute value of the
setting in No. 1975 (Series 15) or No. 2082 (Series 16). Stage 2
acceleration ends at a distance two times greater than the start point
distance if the value set in No. 1975 (Series 15) or No. 2082 (Series 16)
is positive; if the value is negative, stage 2 acceleration ends at a
distance three times greater than the start point distance.
If No. 1982 (Series 15) or No. 2089 (Series 16) is set to a non-zero
value, the end point of the stage 2 acceleration can be set to an arbitrary
point.
(Example)
When No. 1975 (Series 15) or No. 2082 (Series 16) = 10, and No.
1982 (Series 15) or No. 2089 (Series 16) = 50 (meaning
multiplication by 5), acceleration is performed as follows:
Fig. 4.6.5 (d) Stage 2 end scale factor
Stage 2 acceleration
amount
Stage 1 acceleration
amount
10 50