D. FUNCTION-SPECIFIC SERVO PARAMETERS APPENDIX B-65150E/04
− 364 −
D FUNCTION-SPECIFIC SERVO
PARAMETERS
✰ : Parameters set up automatically or cleared at
initialization
Parenthesized parameters : Common parameters that are also used for
other functions
Parameter number
Series 15
Series 16,
18, 20, 21,
Power Mate
Power
Mate-E
Meaning
[Servo initialization functions]
1804 2000 1000 Initialization bits
1874 2020 1020 Motor number
1806 2001 1001 AMR
1820 1820 100 CMR
1977
1978
2084
2085
1084
1085
Flexible feed gear (numerator)
Flexible feed gear (denominator)
1879 2022 1022 Move direction
1876 2023 1023 Number of velocity pulses
1891 2024 1024 Number of position pulses
1804#0 2000#0 1000#0 1: Multiplies the number of velocity pulses and position
pulses by 10.
1896 1821 324 Reference counter
1875 2021 1021 Load inertia ratio
− 3111#0 − 1: Displays the servo setting screen.
→ 2.1.2
[Vibration suppression functions in the stop state]
1894 2066 1066 250 µs acceleration feedback gain
✰
→ 4.4.1
1959#7 2017#7 − Velocity loop high cycle management function → 4.4.2
1958#3 2016#3 − Function for changing the proportional gain in the stop state
1730 2119 − Function for changing the proportional gain in the stop state:
Stop judgement level
1747#3 2207#3 − 1: The velocity loop proportional gain in the stop state is
50%.
→ 4.4.3
1808#4 2003#4 1003#4 N pulse suppression function
✰
1992 2099 1099 N pulse suppression level
✰
→ 4.4.4
[Machine-resonance suppression functions]
1956#1 2012#1 1012#1 Machine speed feedback function
✰
1981 2088 1088 Machine speed feedback gain
✰
→ 4.5.1
1808#2 2003#2 1003#2 Observer function
✰
1859 2047 1047 Observer coefficient (POA1)
✰
1862 2050 1050 Observer coefficient (POK1)
✰
1863 2051 1051 Observer coefficient (POK2)
✰
1960#1 2018#1 − Function for disabling the observer in the stop state
1730 2119 − Function for disabling the observer in the stop state: Stop
judgement level
→ 4.5.2