5. DETAILS OF PARAMETERS B-65150E/04
− 306 −
HBBL (#5) A backlash compensation amount is
added to the error counter of:
⇒ See Subsec. 4.5.4.
0: Semi-closed loop ← Standard setting
1: Full-closed loop
POLE (#7) The punch/laser switching function is:
0: Not used
1: Used
#7 #6 #5 #4 #3 #2 #1 #0
1955
−
RCCL
2011 1011
RCCL (#5) The actual current torque limit variable
function is:
0: Not used
1: Used ← ★: Do not change
Related parameters:
1995 (Series 15), 2102
(Series 16), and 1102 (Power
Mate-E)
#7 #6 #5 #4 #3 #2 #1 #0
1956
−
STNG VCM2 VCM1 MSFE
2012 1012
MSFE (#1) The machine speed feedback function is:
0: Not used
1: Used
⇒ See Subsec. 4.5.1.
Related parameters:
1981 (Series 15), 2088
(Series 16), and 1088 (Power
Mate-E)
VCM1 (#4) The VCMD waveform signal conversion
on the check board is switched.
VCM2 (#5) Switches the VCMD waveform
conversion value according to the
following list:
⇒ See (5) in Sec. 4.19.
VCM2 VCM1 Number of velocity command
revolution/5 V
0 0 0.9155 rpm
0 1 14 rpm
1 0 234 rpm
1 1 3750 rpm
STNG (#7) In velocity command mode, a software disconnection alarm is:
0: Detected
1: Ignored
#7 #6 #5 #4 #3 #2 #1 #0
1707
−
APTG
2013 1013
APTG (#7)
The α pulse coder software disconnection
monitor is:
⇒ See Sec. 3.2.
0: Not ignored
1: Ignored