4. SERVO FUNCTION DETAILS B-65150E/04
− 180 −
(5) Setting parameters for the fine acceleration/deceleration function, used
separately for cutting and rapid traverse
As mentioned above, set the fine acceleration/deceleration function bit
and the bit for selecting the bell-shaped or linear type.
Then, set the following:
#7 #6 #5 #4 #3 #2 #1 #0
1800 (Series 15i)
−
FFR
1800
−
FFR 1: Enables feed-forward in rapid traverse also.
#7 #6 #5 #4 #3 #2 #1 #0
1742 (Series 15i)
−
FAG0
2202
−
FAG0 1: Enables the fine acceleration/deceleration function, used separately
for cutting and rapid traverse.
In cutting mode, the following parameters are used:
1766 (Series 15i)
−
Fine acceleration/deceleration time constant 2 (ms)
2143
−
[Valid data range] 8 to 64
A value that falls outside this range, if specified, is clamped to the
upper or lower limit.
1767 (Series 15i)
−
Position feed-forward coefficient for cutting (in units of 0.01%)
2144
−
1768 (Series 15i)
−
Velocity feed-forward coefficient for cutting (%)
2145
−
In rapid traverse mode, the following parameters are used:
1702 (Series 15i)
−
Fine acceleration/deceleration time constant (ms)
2109
−
[Valid data range] 8 to 64
A value that falls outside this range, if specified, is clamped to the
upper or lower limit.
NOTE
To enable this bit setting, the power must be turned
off then back on.