4. SERVO FUNCTION DETAILS B-65150E/04
− 220 −
Table 4.14.1 (c) Setting parameters for detection unit of 1 µ (incremental)
Signal pitch PLC0
Number of
velocity
pulses
Number of
position
pulses
AMR conversion
coefficient 1
AMR
conversion
coefficient 2
FFG
numerator
FFG
denominator
20 0 5000 16000 1536 0 5 128
40 0 2500 8000 768 0 5 64
2(*1) 1 5000 (*2) 15360 0 1 256
4(*1) 1 2500 8000 7680 0 1 128
100 0 1000 3200 1200 8 25 128
40.513167 0 2468 7899 1481 9 301 3804
Table 4.14.1 (d) Setting parameters for detection unit of 1 µ (absolute)
Model PLC0
Number of
velocity
pulses
Number of
position
pulses
AMR conversion
coefficient 1
AMR
conversion
coefficient 2
FFG
numerator
FFG
denominator
LC191F 0 1953 6250 600 0 1 10
AT352(*3) 0 391 1250 120 0 1 2
*1 If the number of position/velocity pulses does not fit one word, set
the following bit to 1.
#7 #6 #5 #4 #3 #2 #1 #0
1804
−
PLC0
2000
−
PLC0 (#0) Specifies whether to use the number of velocity or position pulses
without modifying them, as follows:
0: Not to modify
1: Multiply by 10 ← To be set
*2 Because the number of position pulses exceeds 130,000, specify
the position pulse conversion coefficient (supported by Series
90A0/N(14) and subsequent editions).
2628
−
Position pulse conversion coefficient (PSMPYL)
2185
−
Bit for multiplying the number of position/velocity pulses by ten
(PLC0) = 1
Number of pulses (PPLS) = 8000
Position pulse conversion coefficient (PSMPYL) = 2
Regard 160,000 pulses as: (8000*2)*10
*3-a Because the velocity loop proportional gain overflows, set the
following bit to 1 (supported by Series 90A0/I(09) and
subsequent editions).
#7 #6 #5 #4 #3 #2 #1 #0
1740
−
P2EX
2200
−
P2EX (#6) Velocity loop proportional gain (PK2V)
0: Standard format
1: Changes the format ← To be set