B-65150E/04 APPENDIX
B. ANALOG SERVO INTERFACE SETTING PROCEDURE
− 353 −
[Setting example 3: Five analog servo axes + two digital servo axes]
The first analog servo interface unit (including expansion) is slave
1, two digital servo amplifiers are slaves 2 and 3, the second
analog servo interface unit is slave 4, as in the sequence in which
they are connected to the FSSB. Assuming that the analog
amplifiers are connected behind the analog servo interface unit,
they are slaves 5 to 9.
JV12L
JV11L
CNC
FSSB
Analog amplifier 1
Analog amplifier 2
Analog amplifier 3
Analog amplifier 4
FSSB
X-axis
Y-axis
Z-axis
A-axis
B-axis
?????
(Expansion unit)
Analog servo
interface unit
(Basic unit)
Slave 5
JV14L
Digital servo amplifiers
(two axes)
FSSB
Slave 6
Slave 7
Slave 8
Slave 2
JV13L
(Basic unit)
C-axis
U-axis
Slave 3
JV11L
Analog servo
interface unit
Analog servo
interface unit
Analog amplifier 5
Slave 9
FSSB
Slave 4
Slave 1
No.
1080 1081 1082 1083 1084 1085 1086 1087 1088 1089
No.
1910 1911 1912 1913 1914 1915 1916 1917 1918 1919
Set value
1645480123640
Axis
No. 1023 No. 1093 No. 1094 No. 1095
Axis
No. 1023 No. 1905 No. 1936 No. 1937
X
1 01000000 0 0
Y
2 01000000 1 0
Z
3 01000000 2 0
A
4 01000000 3 0
B
5 00000000 0 0
C
6 00000001* 0 0
U
7 10000000 0 0
NOTE) For a digital servo axis even-numbered in parameter No. 1023, specify a slow interface type between