4. SERVO FUNCTION DETAILS B-65150E/04
− 192 −
4.10 BRAKE CONTROL FUNCTION
(1) Overview
This function prevents the tool from dropping vertically when a servo
alarm or emergency stop occurs. The function prevents the motor from
being immediately deactivated, instead keeping the motor activated for
the period specified in the corresponding parameter, until the
mechanical brake is fully applied.
(2) Hardware configuration
Fig. 4.10 (a) Example of configuration
The numbers of the following descriptions correspond to those in the
figure:
<1> Applicable system soft
Any system soft can be used.
<2> Applicable servo soft
Any servo soft can be used.
<3> Servo amplifier
Use a single-axis servo amplifier (SVM1 or single-axis SVU,
SVUC, or C-series amplifier for an axis) to which the brake
control function is applied. See NOTE below.
For an axis to which the brake control function is not applied, any
servo amplifier can be used.
<1>
<2>
<3>
Servo amplifier (SVM + PSM)
200 VAC
X
CNC
System soft
Servo soft
X command
Y command
Z command
X-axis feedback
Y-axis feedback
Z-axis feedback
Y
Z
+24 V or 100 VAC
<5>
<4>
Emergency stop button